Level
ProLev800
#
  • #
Measures the flying time of ultrasonic signal to the sludge level Ultrasonic signal has characteristic that it reflects where the density changes. Submerged sensor transmit ultrasonic signal, then the signal reflects at the interface inside the tank. Some part of signal penetrate into the sludge and it also reflects at the rake or bottom of the tank. Ultrasonic signal transfers in the unclear water. There is no need to contact to the measuring object (sludge), the measurement can be done without sinking the sensor deep into the tank.

ProLev800 
  • Details
  • Technical parameters
  • Installation method
  • Typical application
  • Related products
  • Measures the flying time of ultrasonic signal to the sludge level

    Ultrasonic signal has characteristic that it reflects where the density changes.
    Submerged sensor transmit ultrasonic signal, then the signal reflects at the interface inside the tank. Some part of signal penetrate into the sludge and it also reflects at the rake or bottom of the tank.
    Ultrasonic signal transfers in the unclear water. There is no need to contact to the measuring object (sludge), the measurement can be done without sinking the sensor deep into the tank.

     

     

     

     

     

    Applications:

    Interface management of settling tank at industrial wastewater treatment facility

    Interface management for a settling tank at sewage treatment facility

     

     

    Features:

    □ Measuring range is wide from 0.5 to 10 meters.

    □ One unit can measure two distances from different sensors. 

    □ Thanks to ultrasonic signal, no need to care about clarity of the water, day or night (nob need of light)

    □ Calculation process is prepared for supply water quality or deposited sludge, so no need of extra setting or calibration.

    □ Durable and stable. Both main unit and sensor unit does not consist any mechanical movement part.

  • Model

    PROLEV800

    Channel number

    2 CH

    Frequency

    400 kHz

    Measuring object

    Sludge interface

    Measurement range
    (1/2 for powder

    0.4 - 10 m

    Resolution

    internal

    1 cm

    display

    1 cm

    Data update cycle

    1 second

    Directive angle (half of full angle)

    6 degree

    Power source

    Volgtage

    85 - 264 V AC, 50/60 Hz

    Power

    10 VA

    Display

    LCD (back-lit)

    Output

    Alarm

    2 points
    250V AC, 30V DC, 5 A(relay contat

    4-20 mA current

    resolution: 16 bit / channel
    (Max. load 450Ω)

    Interface

    RS-232Cdistance 10m or less

     

    Model

    Main unit

    Sensor unit

    Operation temperature

    -10 to 60 deg C

    -5 - 60 deg C

    Material

    Painted steel

    Cae: PVC
    Cable: PVC

    Protection

    IP54

    IP68

    Dimension
    WxDxH mm

    28092.5322

    D 8095

    Cord length

    -

    20 m

    Max. cord length

    -

    100 m*

    Weight

    3.6 kg

    2.2 kg

     

  • ultrasonic sluge level meter
  • Ultrasonic Level Meter Prolev200
    Ultrasonic Level Meter Prolev200
    PROLEV200/300 plus is a digital signal processed by a high performance microprocessor Due to the non-contact measurement, the measured medium is almost unlimite...